ASTM D6413 PDF
The (ASTM D) FR Clothing Standard governs the Standard Test Method Flame Resistance of Textiles via vertical testing. ASTM D is the Standard Test Method for Flame Resistance of Textiles ( vertical test). ASTM D is used to determine flame resistance of. ASTM D Test Method for Flame Resistance of Textiles. (Vertical Test). • Pass criteria: max char length of 10 cm. • After-flame of not more than 2 seconds.
Author: | Zululabar Nesar |
Country: | Somalia |
Language: | English (Spanish) |
Genre: | Finance |
Published (Last): | 18 June 2013 |
Pages: | 426 |
PDF File Size: | 7.77 Mb |
ePub File Size: | 15.36 Mb |
ISBN: | 345-8-71863-146-7 |
Downloads: | 90439 |
Price: | Free* [*Free Regsitration Required] |
Uploader: | Dougar |
Refer to Section 14 for single-laboratory precision. Retrieved on March 10, from https: Our webinars, hosted by our knowledgeable technical manager, Mark Saner, are designed to give you valuable information about everything from complying with industry safety standards to proper PPE care and repair. It requires FR fabrics to pass a comprehensive series of thermal tests, including the following:. Our video series provide comprehensive information about a wide variety of FR topics. It has specific requirements on handling flammable substances, however, it does not specifically require FR clothing.
Our entire staff stands ready to provide you with industry solutions and the cutting-edge products you need to make your job safer. The between-laboratory precision of this test method has not been established.
In-stock orders placed before 4PM are shipped same day. For more information on laws and standards related to FR clothing, and how those standards apply to your company, please visit the sources below:.
The test results from the two laboratories should be compared using a statistical test for unpaired data, at a probability level chosen prior to the testing series. The optional FR station wear must meet the non-FR requirements as well as measure up to flammability testing of fabric and other small textile components. It applies to chemical plants and petroleum plants. Our up-to-date technical briefs are designed to help you understand the particular hazards and safety standards that apply to your industry — and the role FR workwear plays in addressing them.
It does not cover safety-related work practices for ships, railway rolling stock, aircraft, underground mines, or communications and utilities equipment. The most important reason to invest in flame-resistant FR clothing: OSHA 5 A 1 General Duty Clause This standard states that each employer shall furnish each of his or her employees with a place of employment free from recognized hazards that cause or are likely to cause death or serious physical harm.
This standard requires employers to identify risks and protect employees from hazards in the workplace. ICS Number Code Fabric must not have more than a maximum of percent predicted body burn after a three-second thermal exposure.
It also states that lab coats should be worn when working with hazardous materials in a laboratory.
ASTM D 6413 Flame Resistance of Textiles
Fabric must not melt or drip, separate or ignite after five minutes in an oven at degrees Fahrenheit. Fabric must not have more than a maximum of two seconds afterflame and a 4-inch char dd6413. This standard states that each employer shall furnish each of his or her employees with a place of employment free from recognized hazards that cause or are likely to cause death or serious physical harm.
Additional Atm For more information on laws and standards related to FR clothing, and how those standards apply to your company, please visit the sources below: QuickTrack is free and has powerful procurement, account management and reporting features. Once the flame is turned off the material continues to burn. This standard outlines the requirements for the design, performance, testing and certification of non-primary protective station and work uniforms.
ASTM D method is a laboratory based test that is used to astk the vertical flame resistance of textiles. The rule applies to many types of personal protective equipment, such as safety glasses, hard hats and safety shoes.
To help you better understand the specific requirements for your industry and workforce, Workrite Uniform Company has compiled the following summaries of FR-related standards. The amount of time this material continues to burn is then recorded – this is known as the “After Flame Time”.
FR Clothing Standards | FR Information
Combining values from the two systems may result in non-conformance with the standard. Technical Briefs for Your Industry Our up-to-date technical briefs are designed to help you understand the particular hazards and safety standards that apply to your industry — and the role FR workwear plays in addressing them. Next a char length measurement is recorded by taking the article and tearing it from the edge of the burn, up to the charred area.
In some instances in which employees had suffered from burns in the workplace, OSHA used this standard to cite employers that did not require the use of FR protective apparel. Small sections of textile are hung, vertically, inside a chamber. No matter how atsm like to order, Gallaway is here to serve.
ASTM D / DM – 15 Standard Test Method for Flame Resistance of Textiles (Vertical Test)
Link to Active This link will always route to the current Active version of the standard. We extend day terms automatically and do not require a minimum order amount for federal, state, county, city, military, college or hospital purchases.
It addresses topics such as hazard assessment, purchasing, cleaning, repairs, storage, decontamination, retiring garments and proper use procedures. As a minimum, the test samples used should be as homogeneous as possible, that are drawn from the material from which the disparate test results are obtained, and that are assigned randomly in equal numbers to each laboratory for testing.
This specification provides performance requirements for clothing worn by electrical utility workers and other personnel working around energized parts.
This is commonly referred to as the “After Glow Time”. Historical Version s – view previous versions of standard. As a locally-owned and -operated distributor, we pride ourselves on the level of service we offer.